Promotional Banner - Delivery in 2-3 hours, Quality & Original, Delivered
New Sale
c0c7c684.jpg
43fab7f4.jpg
Product image
Product image

Hanna HI96712 Aluminum Portable Photometer

SKU.: BC12792470

✓ In stock

The HI96712 portable photometer is for the measurement of aluminum. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards for meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length. SKU HI96712 Name Aluminum Portable Photometer – HI96712 Aluminum Range- 0.00 to 1.00 mg/L Aluminum Resolution- 0.01 mg/L Aluminum Accuracy- ±0.02 mg/L ±4% of reading @ 25°C Aluminum Method- Adaptation of the aluminon method. The reaction between aluminum and reagents causes a reddish tint in the sample. Photometer/Colorimeter Light Source- Tungsten Lamp Photometer/Colorimeter Light Detector -Silicon Photocell with narrow band interference filter @ 525nm Battery Type/Life 9V battery Automatic Shut-Off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Weight -290 g (10 oz.) Dimensions -193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) CAL Check™ – Allows for performance verification and calibration of the meter using NIST traceable standards. GLP – Review of the last calibration date. Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on. Battery status indicator – Indicates the amount of battery life left. Built-in timer – Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed. Error messages – Messages on display alerting to problems including no cap, high zero, and standard too low. Cooling lamp indicator – To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken. Units of measure – Appropriate unit of measure is displayed along with reading.
You can explore our full range of Heavy Machinery.
from 1 USh 1,168,200.00 Incl. 0.16% VAT
💬 Order via WhatsApp